FEATURES & CONFIGURATION

Features & configuration

Divide control tasks

Combine compatible CPUs, such as a PLC CPU for machine sequences and a motion CPU for servo axes.

Expand for the signals you need

Add modules for the signals your equipment uses, including on/off, voltage or current, temperature and high-speed pulses.

Connect equipment and collect data

Use network modules to connect controllers and field devices, and information modules to pass production data to higher-level systems.

SPECIFICATIONS & SELECTION

Key specifications & selection

PLC CPU performance specifications

Compare 13 standard and network-equipped PLC CPUs across eight model groups. R04(EN)CPU, for example, covers both R04CPU and R04ENCPU.

Control specifications shared by all models
Processing methodRuns the stored control program in a cycle
I/O controlI/O refresh, with direct access available through DX and DY
Programming languagesLD (ladder), ST (structured text), FBD (function block diagram), SFC (sequential function chart)
Programming extensionsFunction blocks (FB) and system, local and global labels
Program executionStartup, scan, fixed interval, event and standby

● Supported · – Not supported · EN: EN model only · SD: logs to SD card only

Scroll sideways to compare more models. The specification column stays visible.

Performance and functions by CPU model
SpecificationR00CPUR01CPUR02CPUR04(EN)CPUR08(EN)CPUR16(EN)CPUR32(EN)CPUR120(EN)CPU
Control timing and I/O
I/O points (X/Y)4,0964,0964,0964,0964,0964,0964,0964,096
Constant scan (ms)0.5–2,0000.5–2,0000.5–2,0000.2–2,0000.2–2,0000.2–2,0000.2–2,0000.2–2,000
Memory capacity
Program capacity (steps)10K15K20K40K80K160K320K1,200K
Program memory (bytes)40K60K80K160K320K640K1,280K4,800K
Device/label memory (bytes)252K252K252K400K1,188K1,720K2,316K3,380K
Data memory (bytes)1.5M1.5M1.5M2M5M10M20M40M
Instruction performance
LD instruction (ns)31.331.33.920.980.980.980.980.98
MOV instruction (ns)62.762.77.841.961.961.961.961.96
E+ floating-point addition (ns)100.0100.017.69.89.89.89.89.8
ST IF instruction (ns)31.331.33.921.961.961.961.961.96
ST FOR instruction (ns)31.331.33.921.961.961.961.961.96
PC MIX (instructions/µs)1919146419419419419419
Communication ports and memory interfaces
Hi-Speed USB 2.0 (Mini-B)●●●●●●●●
Built-in Ethernet · 100/10 Mbps●●●●●●●●
CC-Link IE network section · 1,000/100/10 Mbps–––ENENENENEN
CC-Link IE Field Network Basic · 100/10 Mbps●●●●●●●●
SD memory card–●●●●●●●
Extended SRAM cassette–––●●●●●
Supported functions
Multiple interrupts●●●●●●●●
Standard PID control●●●●●●●●
Built-in database–––●●●●●
Memory dump–●●●●●●●
Data logging–SDSD●●●●●
Real-time monitoring●●●●●●●●
Security●●●●●●●●
Inter-module synchronization●●●●●●●●
SLMP communication●●●●●●●●
Simple CPU communication●●●●●●●●
Web server●●●●●●●●

How to read the performance figures

Instruction time and machine response
LD reads a contact state in ladder logic, while MOV transfers a value. The ns values describe individual instructions. An ST IF or FOR statement can execute multiple instructions depending on its condition and number of iterations. PC MIX compares how many basic and data instructions the CPU processes per microsecond on average.
Constant scan and the control cycle
A PLC scan is the repeating cycle in which the controller executes the program and refreshes I/O. Constant scan keeps that cycle regular and is set in 0.1 ms increments. To estimate the time from sensor input to an output action, also account for the executed code, I/O module response and network refresh cycle.
Memory for logic and operating data
Program capacity expresses logic size in steps; program memory is the space allocated to store it in bytes. Device and label memory holds signals and variables used during operation. Moving from R02CPU to R04CPU raises program capacity from 20K to 40K steps and reduces LD time from 3.92 ns to 0.98 ns. R04 through R120 share the instruction performance shown here, so compare memory against the size of your program and data.

SD cards and expansion memory

An SD card can store logs on supported models. An SRAM cassette expands device and label memory on compatible CPUs. ECC models can correct memory errors.

Manufacturer SD memory cards
ModelTypeCapacity
NZ1MEM-2GBSDSD2 GB
NZ1MEM-4GBSDSDHC4 GB
NZ1MEM-8GBSDSDHC8 GB
NZ1MEM-16GBSDSDHC16 GB

R00CPU does not support SD cards.

Extended SRAM cassettes by CPU type
ModelCapacityECCPLCProcess / SIL2Safety
NZ2MC-1MBS1 MB–Yes–Yes
NZ2MC-2MBS2 MB–Yes–Yes
NZ2MC-2MBSE2 MBYes–YesYes
NZ2MC-4MBS4 MB–Yes–Yes
NZ2MC-8MBS8 MB–Yes–Yes
NZ2MC-8MBSE8 MBYes–YesYes
NZ2MC-16MBS16 MB–Yes––

The PLC column excludes R00CPU, R01CPU and R02CPU. The process column covers both process and SIL2 process CPUs.

Diagram showing a CPU connected to a programming computer, field network and SD card
CPU connections by function · schematic
Programming and diagnostics
USB 2.0 Mini-B and 10/100 Mbps Ethernet are standard. Configure the CPU with GX Works3 and check its status through the built-in web server.
Network-equipped CPUs
The two-port network section on EN models supports Ethernet, CC-Link IE Field and CC-Link IE Controller (twisted pair). It cannot run two Ethernet networks simultaneously or combine CC-Link IE Field with Controller.
Memory and data logging
R00CPU has no SD slot. R01CPU and R02CPU save logs to SD only. Models from R04 upward support expansion SRAM and a built-in database.

MELSEC iQ-R lineup

Base carrying the power supply, CPU, I/O and control, network and data modules
Module arrangement · schematic
  1. BaseModule mounting
  2. Power supplyPower for modules
  3. CPUSequence control
  4. I/O and controlI/O, metering, pulses and motion
  5. NetworkController and remote I/O links
  6. Data integrationData logging and IT links

Reference: Mitsubishi Electric FA · MELSEC iQ-R PLC CPU specifications and product lineup

What to check before selecting

  • Select the CPU based on the required program capacity and network.
  • Size the base and power supply for the installed modules, spare slots and power demand.
  • Select expansion modules based on I/O type and count, servo axis count and connected equipment protocols.

DOWNLOAD CENTER

Resources

Manufacturer catalogues, manuals and 2D/3D drawings.

Loading documents…