MITSUBISHI ELECTRIC FR-F800
Manufacturer family image. Appearance varies with model, capacity and options.

MITSUBISHI ELECTRIC

Inverter

FR-F800

Product type
Fan/pump inverter
Series
FREQROL-F800
Typical loads
Fans and pumps
Configuration software
FR Configurator2

Price, supply and delivery are confirmed after checking the exact model.

PRODUCT OVERVIEW

Introducing FR-F800

Inverter for speed control of fan and pump loads. Select the rating and peripheral devices for motor data, load profile and operating method.

PRODUCT FEATURES

Features & configuration

01Design motor operation and signal integration for flow and pressure control.

02Match supply voltage, motor capacity and duty rating to the same ordering code.

Regulate fan and pump speed from process feedback

The drive compares the sensor reading with the setpoint and adjusts motor frequency through PID feedback control. Size the drive for both continuous current and the overload duty of the fan or pump.

Feature reference · Mitsubishi Electric FA

Function diagram · IIE illustration
  1. Pressure or flow sensor
  2. F800 PID control
  3. Fan or pump motor
Product type
Fan/pump inverter
Series
FREQROL-F800
Typical loads
Fans and pumps

SPECIFICATIONS & SELECTION

Specifications & selection

Read model scope, units and conditions together with the values.

Manufacturer performance specifications

Standard configurations by voltage
ModelInput supply classApplicable motor (kW)
FR-F820Three-phase 200 V class0.75–110
FR-F840Three-phase 400 V class0.75–315
FR-F842Three-phase 400 V class355–560
FR-F846Three-phase 400 V class0.75–160

How to read the performance figures

For fans and pumps, PID can regulate speed from pressure or flow feedback. FR-F820-01540-1-60 SLD overload is 110% for 60 s or 120% for 3 s at 40 °C. Output is 0.2–590 Hz, limited to 400 Hz in advanced flux-vector and PM motor control.

Rated current and overload
Compare the motor nameplate current at the same voltage and duty rating. Overload specifications pair a reference current with a time limit. Check heat buildup for repeated operation.
Speed range and deceleration
The output frequency range describes the drive. Set operating speed and deceleration time after checking motor cooling, machine speed limits and regenerated energy.

Performance reference · Mitsubishi Electric FA · FREQROL Lineup / FR-F820-01540-1-60 Specifications

FR-F800 · Product specifications
ItemSpecification
Product typeFan/pump inverter
SeriesFREQROL-F800
Typical loadsFans and pumps
Configuration softwareFR Configurator2

Reference: Mitsubishi Electric FA · Checked 2026-10-27

What to check before selecting

  • Confirm supply, communications, connected devices and installation conditions against the exact ordering code and options.

DOWNLOAD CENTER

Resources

Manufacturer catalogues, manuals and 2D/3D drawings.