MITSUBISHI ELECTRIC
Inverter
FR-F800
- Product type
- Fan/pump inverter
- Series
- FREQROL-F800
- Typical loads
- Fans and pumps
- Configuration software
- FR Configurator2
Price, supply and delivery are confirmed after checking the exact model.
PRODUCT OVERVIEW
Introducing FR-F800
Inverter for speed control of fan and pump loads. Select the rating and peripheral devices for motor data, load profile and operating method.
PRODUCT FEATURES
Features & configuration
01Design motor operation and signal integration for flow and pressure control.
02Match supply voltage, motor capacity and duty rating to the same ordering code.
Regulate fan and pump speed from process feedback
The drive compares the sensor reading with the setpoint and adjusts motor frequency through PID feedback control. Size the drive for both continuous current and the overload duty of the fan or pump.
Feature reference · Mitsubishi Electric FA
- Pressure or flow sensor
- F800 PID control
- Fan or pump motor
- Product type
- Fan/pump inverter
- Series
- FREQROL-F800
- Typical loads
- Fans and pumps
SPECIFICATIONS & SELECTION
Specifications & selection
Read model scope, units and conditions together with the values.
Manufacturer performance specifications
| Model | Input supply class | Applicable motor (kW) |
|---|---|---|
| FR-F820 | Three-phase 200 V class | 0.75–110 |
| FR-F840 | Three-phase 400 V class | 0.75–315 |
| FR-F842 | Three-phase 400 V class | 355–560 |
| FR-F846 | Three-phase 400 V class | 0.75–160 |
How to read the performance figures
For fans and pumps, PID can regulate speed from pressure or flow feedback. FR-F820-01540-1-60 SLD overload is 110% for 60 s or 120% for 3 s at 40 °C. Output is 0.2–590 Hz, limited to 400 Hz in advanced flux-vector and PM motor control.
- Rated current and overload
- Compare the motor nameplate current at the same voltage and duty rating. Overload specifications pair a reference current with a time limit. Check heat buildup for repeated operation.
- Speed range and deceleration
- The output frequency range describes the drive. Set operating speed and deceleration time after checking motor cooling, machine speed limits and regenerated energy.
Performance reference · Mitsubishi Electric FA · FREQROL Lineup / FR-F820-01540-1-60 Specifications
| Item | Specification |
|---|---|
| Product type | Fan/pump inverter |
| Series | FREQROL-F800 |
| Typical loads | Fans and pumps |
| Configuration software | FR Configurator2 |
Reference: Mitsubishi Electric FA · Checked 2026-10-27
What to check before selecting
- Confirm supply, communications, connected devices and installation conditions against the exact ordering code and options.
DOWNLOAD CENTER
Resources
Manufacturer catalogues, manuals and 2D/3D drawings.
Loading documents…