DELTA VFD-B
Manufacturer product image. Refer to the exact order code for configuration.

DELTA

Inverter

VFD-B

Standard output frequency
0.1–400 Hz
Communication
Modbus · up to 38,400 bps
Multi-step speed
16 speed steps / 15 preset process steps
Manufacturer status
Discontinued · evaluate MS300 / MH300 / C2000 Plus

Price, supply and delivery are confirmed after checking the exact model.

PRODUCT OVERVIEW

Introducing VFD-B

General-purpose inverter family with open- and closed-loop vector control. Review servicing or successor selection against torque and feedback requirements.

PRODUCT FEATURES

Features & configuration

01Review rated motor current, duty profile, operating speed and braking together.

Use vector control to handle load changes

Open-loop control runs without a motor encoder, while a closed-loop arrangement reads the encoder to correct actual speed. For a replacement in a closed-loop machine, match the feedback option and signal format.

Feature reference · Delta Electronics

Function diagram · IIE illustration
  1. Speed reference
  2. VFD-B vector control
  3. Motor and feedback
Standard output frequency
0.1–400 Hz
Communication
Modbus · up to 38,400 bps
Multi-step speed
16 speed steps / 15 preset process steps

SPECIFICATIONS & SELECTION

Specifications & selection

Read model scope, units and conditions together with the values.

Manufacturer performance specifications

Operating performance and functions
ItemSpecification
Output frequency0.1–400 Hz
Constant-torque vector controlOpen loop / closed loop
Operating presets16 speed steps / 15 presets
Built-in serialModbus · ≤ 38,400 bps

How to read the performance figures

The standard range is 0.1–400 Hz. Delta's optional 2,000 Hz high-speed output was factory programmed, so check the installed version. Open- and closed-loop operation differ in motor feedback requirements. Check the installed encoder and signal type.

Rated current and overload
Compare the motor nameplate current at the same voltage and duty rating. Overload specifications pair a reference current with a time limit. Check heat buildup for repeated operation.
Speed range and deceleration
The output frequency range describes the drive. Set operating speed and deceleration time after checking motor cooling, machine speed limits and regenerated energy.

Performance reference · Delta Electronics · VFD-B Series Product Specifications

VFD-B · Product specifications
ItemSpecification
Standard output frequency0.1–400 Hz
CommunicationModbus · up to 38,400 bps
Multi-step speed16 speed steps / 15 preset process steps
Manufacturer statusDiscontinued · evaluate MS300 / MH300 / C2000 Plus

Reference: Delta Electronics · Checked 2026-10-27

What to check before selecting

  • Distinguish the series name from the exact order code, and check connected devices, supply, interfaces and mounting conditions.

DOWNLOAD CENTER

Resources

Manufacturer catalogues, manuals and 2D/3D drawings.

Loading documents…